Due to a planned power outage, our services will be reduced today (June 15) starting at 8:30am PDT until the work is complete. We apologize for the inconvenience.
DTIC ADA382681: Computation Curves for Axi-Symmetric Base Pressure Analysis
The conical pressure rise theory for separated flows, which was developed by the first author in Ref. 1, has been adapted for calculating axi-symmetric body base pressure in this technical note. The computation complexity of the theory has been reduced by the provision of auxiliary curves, plotted as Figures 2 to 21. Furthermore, several typical solutions for steady flow have been calculated for M=1.5, 2.0, 3.0, 4, and 5 in order to check the theory with some published experimental results.